Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile

Cooking Smell from Upstairs Even with the Flap Shut? NL-HDC-6 Range Hood Flue Check Valve Open-Close and Smoke Transfer Bench, 6 Stations

Popularity:7Time of publication:2026/11/19 9:17:41

The neighbour fries food and the smell arrives in your kitchen first; the hood shows a healthy airflow figure yet smoke still seeps past the flap. A shared-flue check valve opens on suction and closes by spring or gravity, and condensed grease films the flap spindle and seat until two failures arrive together: a stiff flap eats part of the hood airflow, and an incomplete seal lets smoke transfer day and night. Incoming inspection usually just flips the flap by hand and checks the spring returns; opening pressure, reverse leakage, torque after grease ageing and jam rate after life cycling never reach a data sheet. Change the flap material or the spring stiffness and the outcome only shows three years later inside the building, where the only remedy is a full swap.

What the NL-HDC-6 flue check valve open-close and smoke transfer bench measures

  • Six stations with quick-change fixtures for hood-mounted valves, bare valves and flap assemblies (a kitchen air-path component branch)
  • Opening pressure: suction from 10 to 80 Pa in steps, full-open moment and opening pressure distribution tabulated
  • Closed sealing: reverse pressurisation from 20 to 200 Pa, reverse leakage measured point by point with the flap shut
  • Smoke transfer quantified: tracer-gas concentration method, transfer concentration and time curves under a simulated adjacent-source duty
  • Grease ageing: artificial oil-mist chamber at 0, 300 and 600 h, open-close torque and opening pressure change compared per stage
  • Life cycling: fifty thousand open-close cycles compressed, jamming, abnormal noise and full-close rate logged together
  • Whole-unit airflow loss: airflow-static pressure per GB/T 17713 before and after valve fitting, loss in points listed separately
  • Spring stiffness: free length and stiffness decay plotted against cycle count
  • Flap material comparison: ABS, PP, aluminium and stainless flaps on one duty, grease adhesion and torque change on one sheet
  • Velocity distribution: valve-port velocity grid mapping, off-flow and recirculation zones imaged
  • Temperature and humidity: open-close function rechecked in a hot humid kitchen chamber, oil-mist condensation rate recorded
  • Aero-acoustics: valve-port flow noise in one-third octaves, wide and narrow openings compared
  • Differential-pressure channels: air and water path measurements calibrated on a pump performance test basis, tapping and straight-length practice from our pump test bench range ported to the air side
  • Auxiliary systems: chamber temperature, humidity and make-up water on level sensor life test channels
  • Whole-unit link: valves refitted to hoods share the electrical and airflow data chain of our dishwasher test equipment and washing machine test equipment lines
  • Barcode tracking, opening pressure, leakage, torque and jam rate exported on one sheet, flap lot and spring supplier retrievable

Applicable standards

Range hood performance to GB/T 17713, appliance safety to the relevant clauses of GB 4706.1 and GB 4706.28; residential kitchen and bathroom exhaust ducts to JG/T 194; springs to the relevant clauses of GB/T 1239.2. Opening pressure limits, reverse leakage limits and cycle counts can follow the customer standard and the duct supplier specification, sampling to GB/T 2828.

Stations and throughput

Six stations and three fixture families on quick change take one valve design through the full opening pressure and leakage set in a day and complete the grease ageing and life cycling record in a week. “Flips by hand, ships as good” becomes a valve record with opening pressure, leakage and jam rates. Flap material selection, spring stiffness matching, duct supplier comparison and smoke-transfer complaints all settle on one bench.

Manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of range hood flue check valve open-close and smoke transfer benches, washing machine test equipment, dishwasher test equipment, pump test bench ranges, pump performance test systems and level sensor life test machines.

Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.

Recommended products

Ranking of similar articles