Model: NL-LLCZ-5
Cooling plates, condensers and evaporators lose pump power and temperature difference once flow resistance drifts. Incoming checks that only do a leak-pressure test never measure flow and differential pressure at the same working condition, so a blocked batch is discovered only after the part is built into a battery pack, and there is no baseline to argue with the supplier.
The bench measures flow resistance and differential pressure of cooling plates, condensers, evaporators, thermostats, water tanks, oil and water pipes, valves and connectors. A 200L stainless steel tank (1.2mm brushed, with level indicator) feeds a variable-frequency pump; the medium is conditioned in temperature and split to one to five specimen positions in parallel, where inlet and outlet pressure and differential pressure are logged. Working pressure spans 0.1 to 1.2MPa with 0.01MPa accuracy, flow 1.6 to 30L/min within 2 percent FS, differential pressure 1 to 150kPa. Media can be water, oil or a 50 percent glycol and 50 percent water mixture; normal water temperature is 15 to 45C and a heat exchanger option extends the medium to minus 50 to 100C. The controller judges against the limit at the set ambient and medium temperature, for example 15L/min, and records inlet and outlet gauge values; an over-limit specimen raises a prompt and the upper and lower excursion pressures are stored. Test time is settable from 0 to 99 minutes 99 seconds, a PLC with industrial PC collects and stores data for export by USB, the cabinet is explosion proof, and over-pressure and over-temperature stop the machine. A three-station valve flow resistance machine is the standard build and one to five positions are available. Guarding and venting fixtures remove air from the specimen before the test so that air locks do not bias the differential pressure reading. Power is AC380V, 50Hz, 5kW.
GB/T 13927-2008 Industrial valves, pressure testing (shell strength and seat tightness, current); GB 38031-2020 Electric vehicles traction battery safety requirements (liquid cooling clauses); GB 5226.1-2019 Electrical safety of machinery; limits and test conditions follow the customer technical agreement.
Incoming inspection and outgoing flow resistance calibration at cooling plate plants; consistency sampling of automotive condensers, evaporators and thermostats; flow resistance comparison of valves and pipe connectors in heat pump and appliance water circuits; differential pressure testing in third-party laboratories
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.
QQ
Service call
Back to the top