Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile

Too many purifier inspection items for one bench? The NL-JSQ-8 runs eight stations in parallel

Popularity:2Time of publication:2026/11/21 20:57:17

Model: NL-JSQ-8

The problem

A water purifier leaves the factory needing pure water flow, drain flow, pressure switch open and close points, overall tightness under pressure and water efficiency figures. Manual testing means reconnecting pipes and copying readings for several minutes per unit, with transcription errors on top, and a whole batch waits at the bench.

Capability

The bench arranges eight stations by project: two for pressure tightness and pulsation, one for water efficiency, two for overall purifier performance and three for reliability, running in parallel. Coverage includes pure and drain outlet flow, pump draw performance, pressure switch close and open values, inlet and drain solenoid valve states, overall water tightness including proof and pulsation tests, and overall power with water efficiency. Pure water flow spans 0.2 to 2L/min and drain flow 0.3 to 12L/min, both class 1.0; pressure switch close spans 0 to 3.5MPa and open 0 to 0.5MPa at class 0.5. Static and proof pressure is settable 0.05 to 3.5MPa, pulsation 0.01 to 1MPa at 5 to 30 cycles per minute with 0 to 999999 cycles, and hydrostatic proof runs to 1.2MPa; supply pressure accuracy is plus or minus 1 percent. The 0-4MPa pressure sensor holds 0.5 percent accuracy sampling above 900Hz, temperature spans 0 to 100C at 0.5 percent, liquid level 0 to 1000mm at 0.5 percent, and media temperature is adjustable 5 to 45C. A 200L double wall insulated raw water tank with 304 lining refills automatically; a DTD conductivity meter identifies cross flow inside membrane housings and an inline conductivity meter dosing system supports water efficiency and recovery ratio determination. Purifier supply spans 0-300V, current 0-2A and overall power 0-500W; test counts run 1 to 99999 with 60 to 100 seconds per cycle excluding filling. Every station outlet carries a small pressure stabilising tank upstream; a high flow electric pump starts frequently at full load, the drive handles strong overload, analog input conversion takes under 250 microseconds and a network port opens data to Lims systems. The MCGS supervisory platform with PLC replays test curves, prints reports and curves and raises sound and light alarms.

NL test equipment

NL test equipment

Applicable standards

GB/T 35937-2018 Performance test methods for household and similar drinking water treatment units (current); GB/T 30307-2023 Household and similar drinking water treatment units (current, replaces the 2013 edition); QB/T 4144-2019 Household and similar pure water treatment units (current); GB 34914-2021 Minimum allowable values of water efficiency and grades for water purifiers (current, in force from 2022-07-01); water efficiency judgement follows GB 34914-2021 and the customer agreement.

Key specifications

  • Stations: 8 (proof and pulsation 2, water efficiency 1, overall performance 2, reliability 3)
  • Pure water flow: 0.2 to 2L/min, class 1.0
  • Drain flow: 0.3 to 12L/min, class 1.0
  • Pressure switch: close 0-3.5MPa, open 0-0.5MPa, class 0.5
  • Static and proof: 0.05 to 3.5MPa settable; hydrostatic to 1.2MPa
  • Pulsation: 0.01 to 1MPa, 5-30 cycles per minute, 0 to 999999 cycles
  • Pressure accuracy: system plus or minus 1 percent; sensor 0-4MPa class 0.5 above 900Hz
  • Temperature and level: 0-100C class 0.5; level 0-1000mm class 0.5; media 5-45C
  • Raw water tank: 200L insulated 304 lining with conductivity cross flow check
  • Electrical: supply 0-300V, current 0-2A, power 0-500W
  • Rhythm: counts 1-99999, 60-100 seconds per cycle excluding filling
  • Control: MCGS supervisory plus PLC, curve replay, report printing, Lims interface

Applications

Factory overall performance inspection at water purifier and RO system plants; water efficiency and recovery ratio testing of reverse osmosis and nanofiltration models; pressure and pulsation reliability verification of filter housings; water efficiency grade sampling of drinking water treatment units in inspection bodies

About the manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.

Recommended products