Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile

White Rings on Every Glass Even With Rinse Aid Topped Up? NL-RNA-4 Dishwasher Rinse-Aid Dosing and Spot Bench (dishwasher test equipment)

Popularity:9Time of publication:2026/11/17 9:22:56

White water rings on glasses and films on stainless after a dishwasher cycle send the user straight to the rinse-aid bottle. Topped up, the rings stay, because the fault sits on the dosing side. Rinse-aid pumps are mostly peristaltic or solenoid types delivering tens to hundreds of microlitres per shot by squeezing a tube. A tube that has lost its rebound, an aid whose viscosity climbs as the water cools, or a dosing pulse that fires after the final rinse has already started — any one of these pulls the delivered volume off setpoint. In winter, with colder water and thicker aid, the same setting can deliver twenty to thirty percent less; if the nozzle waits until the rinse fill has begun, the dose leaves with the water. Plant acceptance looks at the washed appearance and the drying result; the dose itself is never metered shot by shot. How much per shot, how many shots, at what moment, with what cumulative error — all a black box. After-sales can only suggest adding more, and more means foam spilling into the cavity while less means the rings return.

What the NL-RNA-4 rinse-aid dosing and spot bench measures

  • Four stations with quick-change mounts for peristaltic, solenoid and venturi dosing units (the detergent-dosing branch of our dishwasher test equipment lines)
  • Per-shot volume: micro-balance weighing at 0.1 mg resolution, linearity and repeatability across 0.5–5 mL settings
  • Viscosity-temperature behaviour: 5–40 °C bath, delivered volume offset for one tube across viscosities
  • Dosing phase: logged together with the final-rinse fill valve and circulation pump, phase offset of the dosing window measured per shot
  • Venturi dosing: inlet pressure against induced volume, dilution ratio stability under supply pressure variation
  • Tube ageing: silicone and fluoro-rubber tubes to fifty thousand squeezes, delivered volume decay and wall rebound tabulated together
  • Crystallisation and dry running: hard water and concentrated aid alternating, dry-run rate after head crystallisation logged per stage
  • Spot evaluation: standard glasses, stainless plates and plastic boxes, spot area and haze quantified by image analysis after the cycle
  • Gloss: 60° gloss meter per item, spot area cross-checked against gloss loss
  • Foam control: foam height in the cavity at over-dose, antifoam formulations compared
  • Full-cycle link: complete wash programme run, dose logged against water and energy use and the drying result on one sheet
  • Rinse temperature: final rinse 40–70 °C in steps, the temperature contribution to spotting separated
  • Supply basis: fill water held on pump test bench and pump performance test constant-pressure constant-flow bases, pressure ripple kept out of the dose data
  • Level channels: rinse-aid reservoir and tank levels on level sensor life test lines, the low-level prompt reproduced
  • Cross-category: detergent dosing and residue methods shared with washing machine test equipment lines
  • Barcode binding, per-shot volume, dosing phase, spot area and gloss exported on one sheet, pump lot and aid formulation traceable

Applicable standards

Household dishwasher performance to GB/T 20290 (IEC 60436 basis), washing, drying, water and energy use to its relevant clauses; water efficiency to GB 38383; appliance safety to the relevant clauses of GB 4706.1 and GB 4706.5. Dose tolerance, item appearance acceptance and foam height limits can follow the customer standard and the aid supplier specification, sampling to GB/T 2828.

Stations and throughput

Four stations and three dosing families on quick change take one pump through full-range metering and phase calibration in a day and complete the tube-ageing and viscosity matrix in a week. “Tell the user to add more” becomes a dosing record with per-shot volume, phase offset and spot area. Tube selection, programme calibration and spot complaints all settle on one bench.

Manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of dishwasher rinse-aid dosing and spot benches, dishwasher test equipment, washing machine test equipment, pump test bench ranges, pump performance test systems and level sensor life test machines.

Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.

Recommended products

Ranking of similar articles

Latest news articles