Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile

A Pool of Water in the Cabinet Overnight and the Leak Protector Never Shut Off? NL-LKP-4 Water Purifier Leak Protector and Faucet Outlet Bench (pump performance test)

Popularity:10Time of publication:2026/11/17 9:19:46

What troubles a water purifier is not the water quality but the puddle under the cabinet. The leak protector is the last gate at the outlet — a mechanical float type that lifts a float in a drip tray to cut the inlet, an electronic probe type that conducts when electrodes see water, or a flow type that times out on a small continuous flow. Each principle fails its own way: a float jams on its guide and never drops back, a scaled probe loses the sensitivity to detect anything, a flow type mistakes a normal draw for a leak or reads a slow seep as normal top-up. After assembly the plant runs one pressure hold, and the trip flow, trip time, reset consistency and nuisance-trip rate of the protector — along with faucet outlet flow and shut-off sealing — are never measured on a bench. A puddle complaint ends with the whole unit replaced, and whether the protector failed to act or the valve body seeped is never established, so the next unit from the same lot repeats it.

What the NL-LKP-4 leak protector and faucet outlet bench measures

  • Six stations with quick-change mounts for float, probe and flow protectors plus complete inlet valve groups (the purifier branch of our pump performance test supply lines)
  • Trip point: simulated leak flow 5–200 mL/min in steps, trip flow threshold, trip time and residual pressure after shut-off logged per step
  • Slow leak detection: 0.5–5 mL/min injected over long periods, detection delay and missed-detection rate of flow types tabulated
  • Probe sensitivity: conduction resistance and trip threshold drift after hard-water scaling cycles
  • Float reset: reset time and jam rate after the water level drops, guide tilt from 0 to 3° in steps
  • Nuisance tripping: normal draw of 0.5–3 L/min opened and closed two thousand times each, false shut-offs counted and classified
  • Recovery consistency: trip point regression after power loss, water loss and manual reset
  • Faucet outlet: flow-versus-pressure curve, 30-minute pressure drop after closing (valve seat sealing), aerator flow uniformity
  • Unit pressure hold: 0.6–1.2 MPa held for 30 minutes, drop logged without disturbing the protector trip values
  • Water hammer: 0.3–1.0 MPa cycling to one hundred thousand strokes, trip point shift and body deformation
  • Freeze-thaw: −10 to 20 °C cycles, cracking of float and probe chambers and loss of function
  • Supply and standby: standby current of battery types, low-battery prompt, failure mode after power loss
  • Level channels: raw water tank and pressure vessel levels on level sensor life test lines, dry-run and leak signals kept apart
  • Supply and loop basis: inlet held on a pump test bench constant-pressure basis, flow-versus-pressure curves calibrated to pump performance test practice
  • Cross-category: whole-appliance safety and endurance methods shared with dishwasher test equipment and washing machine test equipment lines
  • Barcode binding, trip flow, trip time, false-trip count and outlet flow exported on one sheet, protector lot and valve supplier traceable

Applicable standards

Household and similar drinking water treatment units to GB/T 30307, construction safety, sealing and function to its relevant clauses; valve and pipe pressure testing to GB/T 13927 practice; appliance safety to the relevant clauses of GB 4706.1. Trip flow thresholds, allowed false-trip counts and the freeze-thaw programme can follow the customer standard, sampling to GB/T 2828.

Stations and throughput

Six stations and three protector families on quick change take one protector through the full trip and nuisance-trip range in a day and complete the water-hammer and freeze-thaw failure record in a week. “A puddle means replace the unit” becomes a component report with trip flow, trip time and false-trip count. Protector selection, incoming grading and puddle complaints all settle on one bench.

Manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of water purifier leak protector and faucet outlet benches, pump performance test systems, pump test bench ranges, level sensor life test machines, dishwasher test equipment and washing machine test equipment.

Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.

Recommended products

Ranking of similar articles

Latest news articles