Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile

Two states, two gauge hook-ups by hand? One clamping runs 25bar closed and open states in sequence

Popularity:8Time of publication:2026/11/10 20:46:17

Model: NL-KFZFJ-2

The problem

The steam valve carries both the milk frothing path and the pressure relief path. If the closed state does not seal, 25bar of boiler pressure escapes from port B straight to the steam outlet; if the open state leaks anywhere, steam sprays where it should not. The part is assessed in two states: closed state, pressurise port A to 25bar and port B must not leak; open state, pressurise A to 25bar and neither B nor C may leak. Manual checking needs two gauge hook-ups and a state change, judged by eye on a needle, and the line takt simply cannot fit it in.

Capability

The bench compresses both states into one takt. The valve seats into a quick-change aluminium fixture, a cylinder clamps it and the pneumatic quick coupling connects in one action; the program first runs the closed state at 25bar against port B, then switches to the open state at 25bar against ports B and C, and any leak lights the lamp and locks that cavity. A 0-2.5MPa adjustable booster pump holds accuracy at 0.01MPa, with boost and release times each settable over 0-99.99s and a 0-99999 cycle counter. Two stations, each with twin cavities, take four 75x45x65mm valves per batch of about 30s - a standard takt of 125 machines per hour. The PLC is selectable among Siemens, Mitsubishi and Omron, low-voltage electrics are Schneider, and pressure releases automatically before the fixture opens.

NL test equipment

Applicable standards

The assessment follows the structural safety clauses (pressurised parts and over-pressure protection) of Chapter 22 of GB 4706.1 General requirements for household and similar electrical appliances, with whole-machine safety under GB/T 4706.19-2024 for liquid heating appliances; the 25bar two-state test pressure, hold times and leak criteria follow the customer technical agreement and the valve drawing.

Key specifications

  • Stations: 2, twin cavities per station, 4 valves per batch
  • Test piece: coffee machine steam valve (relief valve), 75x45x65mm
  • Closed state: 25bar at port A, port B no leak
  • Open state: 25bar at port A, ports B and C no leak
  • Test pressure: 0-2.5MPa (0-25bar) adjustable
  • Pressure accuracy: 0.01MPa
  • Booster pump: 0-2.5MPa adjustable
  • Timing: boost and release each 0-99.99s settable
  • Cycles: 0-99999 settable
  • Fixture: quick-change aluminium, cylinder clamping
  • Method: water test, editable test program
  • Standard takt: 125 machines per hour
  • Control: PLC Siemens / Mitsubishi / Omron optional; Schneider low-voltage electrics
  • Supply: AC220V plus or minus 10 percent, 50/60Hz

Applications

Incoming inspection and line sampling of steam valves at coffee machine plants; shipment inspection at steam valve and relief valve suppliers; milk-system component validation and re-judgement of returned parts

About the manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.