A dishwasher inlet is connected to the drinking-water main while the cavity holds dirty wash water. The two are separated only by the inlet valve plus an air break — a breather or an air gap. During fill, water falls through the gap; when the valve closes, mains water cannot be drawn back into the cavity by negative pressure; during drain, the breather admits air so the cavity does not pull a vacuum and stall drainage. Block that structure with detergent foam, scale or debris and the failure is quiet: under night-time mains negative pressure dirty water siphons back into the drinking-water line, a water-quality red line, or drainage slows and residual water turns the cavity stale, which the user reads as “the drain is sluggish”. Line testing covers fill on-off, overflow and a pressure test. Air gap height, intake flow and the sealing boundary under negative pressure have no number.
Back-siphonage and inlet hose-set requirements with reference to IEC 61770 (cited by GB 4706.25); machine safety to GB 4706.1 and GB 4706.25 (IEC 60335-2-5 basis); drainage and residual-water performance to GB/T 20290 and IEC 60436. Gap-height limits and backflow criteria can follow the customer standard, sampling to GB/T 2828.
Six stations and three structural designs deliver a full record from a new part to the blocking limit within a week. The fill on-off check becomes a backflow report with gap dimensions, intake-flow curves and a siphonage verdict. Incoming breathers, whole-machine water-path matching and after-sales stale-odour complaints share one bench.
Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of air-break and backflow benches, dishwasher test equipment, washing machine test equipment, pump test bench ranges, pump performance test systems and level sensor life test machines.
Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.