Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile

Pump Loses Head Right After a Pre-Filter Is Fitted? NL-PFS-6 Inlet Pre-Filter Clogging Pressure and Flow Decay Bench (pump performance test)

Popularity:12Time of publication:2026/11/8 9:13:50

The pre-filter is the gatekeeper on a pump inlet, holding back the sand, rust and suspended solids carried by well water, river water and secondary supply. Clogging is a slow variable: mesh pores fill up bit by bit, inlet differential pressure creeps from a few hundredths of a bar to a few tenths, suction conditions worsen, flow and head both slide, cavitation noise appears and impeller pitting starts — while the user only calls service when “the water got smaller”. Line inspection usually covers an accuracy spot check and a burst test. The clogging curve, the coupled decay of pressure and flow, and the recovery rate after backwashing have no number at all. Pump verification has a pump performance test rig; the filter itself never had a dedicated clogging-life bench.

What the NL-PFS-6 clogging bench measures

  • Six stations with programmable dosing of sand, rust and suspended solids by ratio and particle distribution (the inlet-filtration post of our pump performance test pump range)
  • Clogging curve: differential pressure logged throughout, pressure versus accumulated retention in one run, service life expressed in hours
  • Coupled flow-head decay: pump sweeps at each clogging stage, suction worsening and head drop tabulated together
  • Accuracy decay: cut-off particle size of the new mesh versus mid-life mesh, drift judged directly
  • Backwash recovery: pressure and flow before and after each backwash, recovery rate logged, decay onset reproduced
  • Mesh comparison: stainless mesh, disc and PP cartridge under identical duty, clogging patterns tabulated
  • Cavitation observation: noise and impeller state recorded at end-of-life clogging, dry-run protection verified per unit
  • Supply regulation and solids loop carried by a pump test bench module, identical conditions across stations
  • Pressure and level signals on the level sensor life test acquisition chain, long-run data comparable
  • Barcode binding, pressure curves, recovery rates and cut-off sizes exported per unit for mesh and lot comparison

Applicable standards

Filtration accuracy and inlet water quality assessed with reference to GB/T 30307 (household drinking-water treatment devices), wetted parts to GB/T 17219. Clogging pressure, flow decay and backwash recovery follow the customer standard, pump-side performance on a GB/T 3216 basis, sampling to GB/T 2828.

Stations and throughput

Six stations with programmable dosing deliver a full decay history from new mesh to the clogging limit within a week. The “accuracy spot check plus burst” sampling becomes a clogging report with pressure curves, recovery rates and coupled-decay records. Incoming meshes, pump-inlet matching and after-sales low-flow complaints share one bench.

Manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of pre-filter clogging benches, pump performance test systems, pump test bench ranges, level sensor life test machines, dishwasher test equipment and washing machine test equipment.

Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.

Recommended products

Ranking of similar articles

Latest news articles