Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile

Leak Tests Passing on the Early Shift and Failing Later? NL-LKT-6 Differential Pressure Leak Test Drift and Volume Correction Bench, 6 Stations

Popularity:1Time of publication:2026/11/24 9:20:02

A leak test bench sits on the shop floor, and the same part passes on the early shift and fails after lunch. With no other option, operators widen the limits by two steps, and real leaks go out with the good parts. A differential pressure test measures a pressure change, and pressure follows temperature: parts arrive warm from the wash line, the shop swings eight to ten degrees between day and night, and fixture and manifold volumes differ at every station, so the same leak rate can read several times apart. Shorten the test time and drift takes a larger share, until a leak of a few millilitres per hour sits below the noise band. Factory routines usually say only that the pressure drop over 30 seconds must stay under a value. Drift compensation, volume correction, minimum detectable leak and repeat-decision agreement, the items that actually set detection capability, stay off the sheet. Change a fixture or a batch of O-rings and sensitivity moves without anyone noticing.

What the NL-LKT-6 differential pressure leak test drift and volume correction bench measures

  • Six stations, absolute pressure, differential pressure and flow methods switchable, fixtures on quick change
  • Drift compensation: reference and part cavities measured together, readings compared with compensation on and off, -5 to +15 °C steps
  • Volume correction: 0.5, 2 and 5 L fixture volumes, pressure-drop conversion factor and correction table for one leak rate
  • Minimum detectable leak: equivalent leak rate at three sigma of the noise band, plotted against test time
  • Test time: fill, settle and measure split, effect on detection capability and cycle time
  • Calibrated leaks: capillary, orifice and permeation types, certified values and temperature coefficients
  • Warm parts: 5, 10 and 20 °C residual heat, reading offset and compensation result
  • Slow leak hold: 0.5, 2 and 10 mL/min, cumulative pressure drop over a 10 min hold
  • Fixtures and O-rings: compression, wear and assembly offset, baseline shift and false-leak signature
  • Coarse and fine: pressure decay coarse check plus differential fine check, big leaks kept off the fine cycle
  • Cross-check: the same part run on differential pressure and helium mass spectrometry, deviation statistics
  • Environment: tempered fixtures and a 10 to 35 °C chamber, temperature gradient logged along manifold and valves
  • Data traceability: barcode binding, SPC trends, repeat-decision agreement counts
  • Water path: supply and hold pressure calibrated on a pump performance test basis, regulated supply from our pump test bench platform
  • Level channel: water-bath level and make-up on level sensor life test channels
  • Whole-unit link: shares calibrated leaks and report templates with the tub and door sealing stations of our dishwasher test equipment and washing machine test equipment lines

Applicable standards

Tracer gas leak testing to GB/T 15823 (helium mass spectrometer method), pressure and tightness testing to GB/T 13927 and the ISO 5208 basis, pressure part test requirements to GB/T 150, appliance safety to GB 4706.1, sampling to GB/T 2828. Leak limits, test times and repeatability requirements can follow the customer standard.

Stations and throughput

Six stations and three switchable methods take one fixture through volume correction, drift compensation and calibrated-leak certification in a day, and complete warm-part steps, slow-leak holds and a helium cross-check in a week. “Pressure drop within limits over 30 seconds” becomes a capability record with a correction table, a minimum detectable leak and a repeat-decision history. Fixture design, O-ring selection, test time setting and seasonal misjudgement complaints all settle on one bench.

Manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of differential pressure leak test drift and volume correction benches, dishwasher test equipment, washing machine test equipment, level sensor life test machines, pump test bench ranges and pump performance test systems.

Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.

Recommended products