Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile

Sewage Pump Clogged by One Fibre and Half the Flow Gone? NL-WWP-6 Wastewater Submersible Pump Cutting, Clogging and Head Test Bench, 4 Stations

Popularity:1Time of publication:2026/11/24 9:20:02

A sewage pump drops into a lift station, a basement sump or a grease trap and then stays out of sight for years. When the call finally comes, there are only two symptoms: the water will not go away, or the pump is burnt. The real cause sits in the medium. Hair, fibres and non-woven wipes wrap the impeller and cutter disc, a blunted edge stops cutting, and once solids content rises the flow halves. Cable entries and mechanical seals grind against grit-laden sewage, water enters the motor chamber, and winding insulation falls away within days. A failed level control lets the pump run dry, and ten minutes of dry running is enough to burn a shaft seal. Plant acceptance mostly runs head and flow on clean water; solids, wrapping, cutting and dry running are never tested. Change a cutter material or an impeller clearance and the difference only appears the day the pump is opened.

What the NL-WWP-6 wastewater submersible pump cutting, clogging and head bench measures

  • Four stations with quick-change fixtures for vertical sewage pumps, cutter pumps and self-priming sewage pumps, 50 to 100 mm outlets
  • Clean water performance: head, flow, input power and efficiency curves measured together on a GB/T 12785 basis
  • Solids duty: 0.5, 1 and 2 percent solids with 5, 10 and 20 mm particles, head and flow decay tabulated
  • Fibre wrapping: metered fibre bundles dosed in, wrap count, flow decay and recovery after cleaning
  • Cutter disc: edge blunting at 0, 0.2 and 0.5 mm, cut-through rate, torque ripple and disc temperature
  • Clog reproduction: graded dosing of wipes and non-woven media, clog located, flow knee before lock-up, clearing time
  • Locked rotor and restart: locked rotor current, temperature rise and the required interval before a third restart
  • Dry run protection: level dropped below the suction inlet, trip time, post-stop winding temperature and reset
  • Seal and cable: mechanical seal and cable entry seepage after grit duty, humidity logged inside the motor chamber
  • Insulation and strength: insulation resistance, surge and electric strength before and after immersion
  • Level control: float, electrode and pressure signals, trip level and differential, signal chatter re-checked
  • Vibration and noise: vibration severity, one-third octave noise and bearing temperature under solids duty
  • Long run: 500 h of solids cycling, retained head, cutter wear and seal leakage
  • Water loop: test loop flow and pressure calibrated on a pump performance test basis, steady supply from our pump test bench platform
  • Level channel: sump level and make-up signals logged on level sensor life test channels
  • Whole-unit link: shares water loop, electrical platform and report templates with our dishwasher test equipment and washing machine test equipment lines

Applicable standards

Wastewater submersible pumps to GB/T 24674, test methods to GB/T 12785, rotodynamic pump hydraulic performance to GB/T 3216; enclosure protection re-checked to the IP68 basis of GB/T 4208, motor insulation and temperature rise to the product specification, sampling to GB/T 2828. Solids content, particle size and cycle counts can follow the customer standard.

Stations and throughput

Four stations and three fixture families on quick change take one pump through four clean-water curves and a solids decay curve in a day, and complete fibre wrapping, cutter blunting, locked rotor and dry-run protection records in a week. “Clean-water head is fine, so it ships” becomes a sewage duty record with solids curves, wrap counts and protection timing. Cutter material selection, impeller clearance design, cable seal construction and repeated sump clogging complaints all settle on one bench.

Manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of wastewater submersible pump cutting, clogging and head benches, pump test bench ranges, pump performance test systems, level sensor life test machines, dishwasher test equipment and washing machine test equipment.

Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.

Recommended products