Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile
Your location: Home > 资讯中心
Recommended products

National Sales Hotline

0086-13416787649
Solar load on air conditioners still estimated? The NL-RGZ-1500 brings 400-1500W/m2 sunlight into the lab

Solar load on air conditioners still estimated? The NL-RGZ-1500 brings 400-1500W/m2 sunlight into the lab

Solar load capacity and shell temperature testing of air conditioners; light coupling verification for PV-driven and sto…

2026/11/16 20:44:10

Six pressure tests need three fixture sets? The NL-FWF-1 does them on one bench and plots the curve

Six pressure tests need three fixture sets? The NL-FWF-1 does them on one bench and plots the curve

Type testing and batch sampling at pressure cooker manufacturers; safety valve and relief structure verification at cook…

2026/11/16 20:44:05

Incoming solenoid valves only checked on/off? The NL-DCF-8 covers start-up, sealing, proof, flow and life in one bench

Incoming solenoid valves only checked on/off? The NL-DCF-8 covers start-up, sealing, proof, flow and life in one bench

Factory batch inspection at water valve and inlet valve makers; incoming inspection at dishwasher and washing machine pl…

2026/11/16 20:43:45

No Ignition at Low Flow and Hot-Cold Swings When Two Taps Run? NL-GWH-4 Gas Water Heater Minimum Activation Flow and Outlet Temperature Bench (pump test bench)

No Ignition at Low Flow and Hot-Cold Swings When Two Taps Run? NL-GWH-4 Gas Water Heater Minimum Activation Flow and Outlet Temperature Bench (pump test bench)

Turn the tap down in summer and the heater will not fire; open the kitchen tap and the shower goes hot for a second — minimum flow and temperature response have always been set by ear and by hand.…

2026/11/16 9:22:21

The Fridge Hums for Ages and Never Cools, Yet a New Starter Fixes It? NL-RSP-4 Compressor PTC Starter and Overload Protector Bench (washing machine test equipment)

The Fridge Hums for Ages and Never Cools, Yet a New Starter Fixes It? NL-RSP-4 Compressor PTC Starter and Overload Protector Bench (washing machine test equipment)

A few-yuan starter swapped on site brings the fridge back, yet the same batch will not start another unit — the lot scatter sits in the resistance-temperature curve.…

2026/11/16 9:11:35

Black Pits Along the Cavity Wall and Arcs Cracking Mid-Heat? NL-WGA-4 Microwave Waveguide Port Arcing and Standing-Wave Bench (dishwasher test equipment)

Black Pits Along the Cavity Wall and Arcs Cracking Mid-Heat? NL-WGA-4 Microwave Waveguide Port Arcing and Standing-Wave Bench (dishwasher test equipment)

Those dark pits along the cavity wall are not dirt but arc marks: the waveguide cover is filmed with grease and residue, and the microwave energy piles into a hot spot right at the port.…

2026/11/16 9:11:35