Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile

Five safety items plus a 60-second inter-electrode hold: the NL-PTCXN judges every PTC heater in turn

Popularity:1Time of publication:2026/11/26 20:46:25

Model: NL-PTCXN

The problem

PTC air heaters sit inside the air duct of the whole machine, so any failure in grounding, insulation, hipot, power or leakage is a safety risk. Cold resistance, the 60-second inter-electrode withstand and open-short judgment are spread over several bench instruments and manual records; production lines and incoming inspection need one integrated system that judges and records automatically.

Capability

The NL-PTCXN tests each heater tube in turn: electrical strength, cold resistance, insulation resistance, withstand voltage, inter-electrode withstand, open-short judgment, power test and cooling judgment, with the report recorded automatically. The five safety items - grounding, insulation, hipot, power and leakage - run as one. Grounding resistance covers 10-200A/200 milliohms plus a 10A range of 5-600 milliohms; insulation runs at 500V/1000V up to 1000 megohms; the hipot applies 2000V at 10 mA; the inter-electrode test is adjustable from 450V to 600V with effective hold no shorter than 60 seconds at 450V. Power testing covers 220V/3.3 kW to 220V/6 kW. A built-in 6 kVA inverter source (six-in-one) outputs 150.0-600.0V at a rated 480.0V with accuracy 0.5 percent or better and 0.1V resolution, standard sine wave. Protections cover overcurrent, overload, short circuit, IGBT and transformer overheat, output over/under voltage and phase loss; input over/under voltage alarms; open and short circuits are identified and the machine stops. The safety-test circuit is isolated from the running-test circuit. One insulation withstand takes 4 seconds per piece; after a pass the sequence switches into the 60-second powered inter-electrode hold; after the test cold-air cooling brings the part back to room temperature before unloading. An industrial embedded system runs on a 19-inch true-color LCD (touch screen optional) with USB and RS232/485 interfaces, and data saving, printing, statistics and analysis execute automatically. A dedicated PTC heater fixture with a safety guard is mounted on the table top.

NL test equipment

Applicable standards

GB/T 4706.1-2024 Household and similar appliances, safety, part 1: general requirements (current); grounding, insulation, hipot, power and leakage thresholds follow the safety clauses and the customer acceptance agreement.

Key specifications

  • Object: PTC air heaters for air conditioners, tube by tube
  • Safety items: grounding, insulation, hipot, power, leakage
  • Grounding resistance: 10-200A/200 m-ohm; 10A range 5-600 m-ohm
  • Insulation resistance: 500V/1000V, up to 1000 m-ohm
  • Hipot: 2000V / 10 mA
  • Inter-electrode withstand: 450-600V adjustable, effective hold 60s or longer (450V)
  • Cold resistance: RS485 resistance meter, automatic reading
  • Power test: 220V/3.3 kW to 220V/6 kW
  • Built-in source: 6 kVA inverter, output 150-600.0V, rated 480.0V
  • Voltage accuracy: 0.5 percent or better, resolution 0.1V, standard sine wave
  • Cycle: 4s per piece insulation withstand; 60s inter-electrode hold; cold-air cooling before unload
  • Judgment: open/short identified, machine stops; NG alarm lamp with buzzer
  • Protections: overcurrent, overload, short circuit, IGBT/transformer overheat, over/under voltage, phase loss
  • Isolation: safety-test circuit separated from running-test circuit
  • Display: 19-inch true-color LCD, touch screen optional

Applications

In-line safety testing of PTC air heaters for air conditioners; incoming inspection and type testing of heater assemblies; 100 percent factory screening at heater plants; safety testing at third-party bodies

About the manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.

Related information

Recommended products