The purifier page says CADR 500, yet after a whole night the particle number still falls slowly. The same machine can score differently in two chambers: a filter gasket seated off-center lets air bypass, a particle sensor reads optimistic, a duct revision adds resistance — and production only runs a powered-on ageing check. CADR is a number stacked from the chamber, the aerosol source, the sampling path and the decay fit. Background concentration, door leakage rate, sensor error and filter bypass each push the rated value away from reality. Change a filter supplier or a duct design and the difference only appears on third-party retest day.
Air cleaner test methods to GB/T 18801 (CADR, CCM, energy efficiency, noise), whole-unit safety to GB 4706.45, sampling to GB/T 2828. Chamber size, source configuration and criteria can follow the customer standard.
One chamber takes four to six units through CADR and efficiency files per day, and completes CCM loading, ageing retention and assembly-leakage files in a week. “Ageing runs fine, so it ships” becomes a chamber record with decay curves, leakage checks and sensor comparison. Filter supplier changes, duct revisions, sensor selection and rated-value re-tests all settle in one chamber.
Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of CADR test chambers, pump test bench ranges, pump performance test systems, level sensor life test machines, dishwasher test equipment and washing machine test equipment.
Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.