Air Purifier Runs All Night Yet the Particle Number Barely Moves? NL-ACR-4 CADR Test Chamber with a 30 m3 Background Lab

Popularity:1Time of publication:2026/11/26 9:12:46

The purifier page says CADR 500, yet after a whole night the particle number still falls slowly. The same machine can score differently in two chambers: a filter gasket seated off-center lets air bypass, a particle sensor reads optimistic, a duct revision adds resistance — and production only runs a powered-on ageing check. CADR is a number stacked from the chamber, the aerosol source, the sampling path and the decay fit. Background concentration, door leakage rate, sensor error and filter bypass each push the rated value away from reality. Change a filter supplier or a duct design and the difference only appears on third-party retest day.

What the NL-ACR-4 CADR test chamber measures

  • 30 m³ chamber: background concentration and natural decay measured first, door and line leakage rates verified
  • Particulate CADR: KCl aerosol generation with optical scattering sampling at multiple points, decay-curve fitting, clean air delivery rate tabulated
  • Gaseous CADR: gas-phase generation and decay sampled in parallel, reported separately from the particle channel
  • Natural-decay correction: background and measured decay curves subtracted on a standard basis
  • Energy efficiency: CADR over rated power, ratio tabulated for grading reference
  • CCM: continuous dust loading until CADR falls past half, cumulative mass graded F1 to F4
  • Filter resistance: static pressure and flow curves, pressure drop recorded step by step
  • Fan speeds: CADR, power and noise tabulated together for every speed
  • Noise: chamber acoustic background verified, sound power measured per speed
  • Sensor check: onboard PM readings compared at the same point with a reference instrument, error tabulated
  • Assembly leakage: gasket compression steps, bypass effect on CADR quantified
  • Long-term retention: CADR retention and filter resistance re-checked after 1,000 h ageing
  • Humidity coupling: concentration field and readings under standard and hot-humid conditions
  • Chamber temperature loop: jacket water loop calibrated on a pump performance test basis, circulating supply from our pump test bench platform
  • Level channel: jacket and humidifier make-up levels logged on level sensor life test channels
  • Whole-line link: shares barcodes, acquisition and report templates with our dishwasher test equipment and washing machine test equipment lines

Applicable standards

Air cleaner test methods to GB/T 18801 (CADR, CCM, energy efficiency, noise), whole-unit safety to GB 4706.45, sampling to GB/T 2828. Chamber size, source configuration and criteria can follow the customer standard.

Stations and throughput

One chamber takes four to six units through CADR and efficiency files per day, and completes CCM loading, ageing retention and assembly-leakage files in a week. “Ageing runs fine, so it ships” becomes a chamber record with decay curves, leakage checks and sensor comparison. Filter supplier changes, duct revisions, sensor selection and rated-value re-tests all settle in one chamber.

Manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of CADR test chambers, pump test bench ranges, pump performance test systems, level sensor life test machines, dishwasher test equipment and washing machine test equipment.

Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.