For an atmospheric burner the primary aeration coefficient decides the flame: too little primary air gives a yellow, sooting flame and a rising carbon monoxide level in the flue gas; too much lifts the flame off the port or lights back. The air shutter is the mechanism that sets this coefficient, yet the factory state is an assembler copying a sample plate, and at the customer a different gas or pan support changes everything. Acceptance tests heat input and flue gas CO, but the mapping of shutter opening to aeration coefficient, flame state and flue gas composition is never tabulated: at what opening the yellow flame clears, at what opening lift-off starts, how much gas variation stays inside the safe window. Turning combustion adaptation into data means putting shutter position, gas pressure, flue gas composition and flame images on one sheet.
Domestic gas cooking appliances to GB 16410, heat input, flue gas CO and flame stability to its relevant clauses; general test methods for household gas appliances to GB/T 16411; actuator installation to the equipment maker specification. Limits and gas steps can follow the customer standard, sampling to GB/T 2828.
Six stations map one burner along the shutter axis in a day and complete the adaptation window for three gas steps in a week. “Set it by feel” becomes a combustion adaptation report with opening, coefficient and flue gas data. Shutter release, gas adaptation windows and after-sales yellow-flame complaints all settle on one bench.
Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of gas burner air shutter and primary aeration benches, pump performance test systems, pump test bench ranges, dishwasher test equipment, washing machine test equipment and level sensor life test machines.
Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.