Manual hipot watching misses units and a missed breakdown becomes a batch complaint; failure to cut off at breakdown burns samples and risks safety; and without records there is nothing to show at customer audits.
Measures breakdown voltage and leakage current of specimens and doubles as a high-voltage source for components and complete units. CPU plus large-scale IC control; variac and step-up transformer output AC 0-5kV; on breakdown the protection circuit cuts the high-voltage loop automatically, the 4-digit display flashes and the event is recorded; single auto-test mode completes and records one test; 100V-5kV high-voltage generator, test rod and earth clip; microcomputer timing with pass/fail indication, PLC program, current and voltage meters; 300x430x320mm bench-top size for production lines and labs.
Production-line hipot testing of appliances and parts; factory inspection of cables, transformers, terminals and bakelite; R&D and QC of motors, small appliances and instruments; withstand-voltage testing at labs and metrology bodies
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and lifetime technical service; 12-month warranty and lifetime spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.