Half a Millimetre of Wear-Ring Wear and the Curve Slips? NL-WRG-6 Pump Wear-Ring Clearance and Volumetric Efficiency Bench (pump performance test)

Half a Millimetre of Wear-Ring Wear and the Curve Slips? NL-WRG-6 Pump Wear-Ring Clearance and Volumetric Efficiency Bench (pump performance test)

The wear ring grows from 0.2 to 0.8 mm of clearance with nothing visible outside: the casing looks new, the current reads normal, and the flow quietly drops. Incoming checks are a caliper on two diameters. The NL-WRG-6 pairs clearance with curves on six stations.…

2026/11/3 9:19:43

Jet Fanning Out and Splashing the Countertop? NL-AER-2 Aerator Flow Uniformity and Splash Bench (pump test bench), Six Stations

Jet Fanning Out and Splashing the Countertop? NL-AER-2 Aerator Flow Uniformity and Splash Bench (pump test bench), Six Stations

A few yuan of aerator decides how the whole tap feels: a jet that fans out, water across the worktop, a tap that is loud at night. Incoming checks look for blockage and burrs only. Flow curve, aeration uniformity, splash volume and screen decay are all blank.…

2026/11/2 9:14:08

Static Pressure Held at the Factory, Seam Weeping Two Years Later? NL-DPF-4 Dishwasher Tank Seam Pressure Fatigue Bench (dishwasher test equipment)

Static Pressure Held at the Factory, Seam Weeping Two Years Later? NL-DPF-4 Dishwasher Tank Seam Pressure Fatigue Bench (dishwasher test equipment)

A tank that holds static pressure in the plant starts weeping at a weld heat-affected zone a year or two later, soaking the cabinet and the floor. A static test finds what leaks now, not what cracks after tens of thousands of cycles. The NL-DPF-4 runs cyclic pressure with hot water on four stations.…

2026/11/1 9:09:41

Inlet Timeout Error on Low-Pressure Floors? NL-INL-6 Washing Machine Inlet Strainer Clog and Low-Pressure Start Bench (washing machine test equipment)

Inlet Timeout Error on Low-Pressure Floors? NL-INL-6 Washing Machine Inlet Strainer Clog and Low-Pressure Start Bench (washing machine test equipment)

The washer runs perfectly in the lab, then throws an inlet timeout error on an old apartment block. Silt caking the inlet strainer plus a supply pressure near the start limit is the pairing nobody tests. The NL-INL-6 couples both duties on four stations.…

2026/10/31 9:18:19

Gas Burner Power Swinging and the Proportional Valve Hunting at Low Fire? NL-GPV-6 Leak and Flow-Characteristics Bench (pump performance test)

Gas Burner Power Swinging and the Proportional Valve Hunting at Low Fire? NL-GPV-6 Leak and Flow-Characteristics Bench (pump performance test)

A gas hob whose flame swings and a combi boiler whose water temperature hunts both trace back to the proportional valve: airtightness, flow-linearity and modulation stability must hold at once, and a line that only checks “it flows” sees none of them. The NL-GPV-6 sweeps all twenty points on six stations.…

2026/10/30 9:23:36

Lid Lifted Mid-Spin and the Tub Keeps Turning? NL-LSW-4 Lid Safety Switch and Interlock Bench, Six Stations (washing machine test equipment)

Lid Lifted Mid-Spin and the Tub Keeps Turning? NL-LSW-4 Lid Safety Switch and Interlock Bench, Six Stations (washing machine test equipment)

A lid lifted during the spin and the tub keeps turning — an instant fail in any inspection. Or the opposite: a shudder triggers the switch and the spin dies halfway. Worn contacts, a lazy linkage and vibration false triggers all need cycle-by-cycle proof. The NL-LSW-4 tests both on six stations.…

2026/10/29 9:12:44