Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile
Your location: Home > 资讯中心
Recommended products

National Sales Hotline

0086-13416787649
Floor washer handle pivots failing first? Two-station twist and swing rig runs 0-360deg cycles at 0.1deg accuracy with automatic failure counting

Floor washer handle pivots failing first? Two-station twist and swing rig runs 0-360deg cycles at 0.1deg accuracy with automatic failure counting

Handle shaft and pivot design validation at floor washer plants; bushing, joint and clip supplier comparison; reproducti…

2026/10/26 20:48:49

Heat Pump Dryer Stops Mid-Cycle With a Scorched Smell? NL-LNT-4 Duct Lint and Outlet Temperature Bench, Four Stations (washing machine test equipment)

Heat Pump Dryer Stops Mid-Cycle With a Scorched Smell? NL-LNT-4 Duct Lint and Outlet Temperature Bench, Four Stations (washing machine test equipment)

Heat pump dryers that stop mid-cycle with damp laundry and a scorched smell at the door, the filter matted with a thick layer of lint. Lint passes the first filter, packs the evaporator fins and duct, airflow falls and discharge temperature climbs until the thermal cut-out trips. The NL-LNT-4 packs a whole season of lint in days.…

2026/10/26 9:10:49

Dishes Still Slippery and Smelling of Detergent When the Door Opens? NL-TRB-4 Turbidity Sensor and Dosing Closed-Loop Bench, Six Stations (dishwasher test equipment)

Dishes Still Slippery and Smelling of Detergent When the Door Opens? NL-TRB-4 Turbidity Sensor and Dosing Closed-Loop Bench, Six Stations (dishwasher test equipment)

Dishes that come out slippery with a film on the glass and a detergent smell at the door, or the opposite: greasy plates run on a light-soil program that dosed almost nothing. A sensor window filmed with grease misjudges the load and the dosing pump loses its shot. The NL-TRB-4 closes that loop on six stations.…

2026/10/26 9:10:49

Water Purifier TDS Reading Fine Yet the Filter Light Never Stops Flashing? NL-TDS-4 Probe and Cartridge Life Bench, Six Stations (level sensor life test)

Water Purifier TDS Reading Fine Yet the Filter Light Never Stops Flashing? NL-TDS-4 Probe and Cartridge Life Bench, Six Stations (level sensor life test)

A purifier whose outlet reads a TDS of ten-something while the filter light keeps flashing, or the reverse: a single-digit display and water that already tastes earthy. Scaling probes, polarization and failed temperature compensation shift the reading. The NL-TDS-4 runs probes and cartridges on a real draw-off rhythm.…

2026/10/26 9:10:49

Testing water heater boards inside whole machines? Twin-station bench simulates sensors and a 3kW heater load, cycling life and high-low temperature modes automatically

Testing water heater boards inside whole machines? Twin-station bench simulates sensors and a 3kW heater load, cycling life and high-low temperature modes automatically

Water heater makers incoming inspection and sampling of control and display boards; control solution providers verifying…

2026/10/25 20:52:55

Leakage plug endurance without sore thumbs: five loaded circuits cycle trip, reset and line-earth leak automatically, retesting trip current every n cycles

Leakage plug endurance without sore thumbs: five loaded circuits cycle trip, reset and line-earth leak automatically, retesting trip current every n cycles

Leakage plug makers factory life sampling for water heater and kettle plugs; PRCD and anti-shock adapter supplier incomi…

2026/10/25 20:52:51