Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile
Your location: Home > 资讯中心
Recommended products

National Sales Hotline

0086-13416787649
Coil tightness drop hard to explain? One clamp holds two coils and judges the 0.1MPa drop at 4MPa in 3 minutes

Coil tightness drop hard to explain? One clamp holds two coils and judges the 0.1MPa drop at 4MPa in 3 minutes

Post-braze tightness inspection of air-conditioner coils in DN20 and DN25 sizes; outgoing sealing checks on heat exchang…

2026/11/2 20:41:35

Still measuring three-metre copper tube with a tape? A CNC length machine reads 0.01mm and stores the data

Still measuring three-metre copper tube with a tape? A CNC length machine reads 0.01mm and stores the data

Incoming inspection of copper tube for air-conditioner evaporators and condensers; outgoing sampling at tube processing …

2026/11/2 20:41:27

Jet Fanning Out and Splashing the Countertop? NL-AER-2 Aerator Flow Uniformity and Splash Bench (pump test bench), Six Stations

Jet Fanning Out and Splashing the Countertop? NL-AER-2 Aerator Flow Uniformity and Splash Bench (pump test bench), Six Stations

A few yuan of aerator decides how the whole tap feels: a jet that fans out, water across the worktop, a tap that is loud at night. Incoming checks look for blockage and burrs only. Flow curve, aeration uniformity, splash volume and screen decay are all blank.…

2026/11/2 9:14:08

Salt Rejection Down to 85% in Year Two? NL-ROM-4 RO Membrane Salt-Rejection and Recovery Bench (pump performance test), Four Stations

Salt Rejection Down to 85% in Year Two? NL-ROM-4 RO Membrane Salt-Rejection and Recovery Bench (pump performance test), Four Stations

Factory checks are a TDS pen and a one-minute flow cup. Salt rejection, recovery and concentrate ratio only surface when the customer complains about scale in year two. The differences live in the pressure, temperature and concentrate coupling. Four stations hold both steady.…

2026/11/2 9:14:08

Heating Element Glowing Red and the Thermal Link Still Closed? NL-TSF-6 Thermal-Link Trip Temperature Sorting Bench (dishwasher test equipment)

Heating Element Glowing Red and the Thermal Link Still Closed? NL-TSF-6 Thermal-Link Trip Temperature Sorting Bench (dishwasher test equipment)

A thermal link marked 102 C trips anywhere between 95 and 110 C and still ships. Whether it breaks cleanly, or whether its trip point creeps up after two years in store, is never measured. The NL-TSF-6 runs six oil-bath stations and logs trip point, resistance and ageing shift per piece.…

2026/11/2 9:14:08

A burst inlet hose found in the customer home? A 3-station rig brings 0.5-4.5MPa burst testing in-house

A burst inlet hose found in the customer home? A 3-station rig brings 0.5-4.5MPa burst testing in-house

Pressure and burst validation at inlet-hose plants; incoming inspection of water-circuit parts by appliance makers; pres…

2026/11/1 20:35:24