PET Polyester PCT Tester NL-PCT400 Saturated Steam 105-132C 100%RH Pressure 0.2-2.0kg/cm2 Safety 3.5kg/cm2 0-999 Hours 400x500mm SUS304 Chamber Highly Accelerated Aging
Coating Scratch Tester NL-HGH-1 ISO 12137-2 ISO 1518 Steel Tip Pencil Eraser Solvent Four Modes X0-180mm Y0-200mm 0-100mm/s 999999 Cycles 60 Degree Angle 10N Scratch Force Printed Coatings
Incoming Solenoid Valve Performance and Life Test Bench NL-DCF-8 Eight Stations One Performance Plus Seven Life 1.75MPa Proof 0.03 and 0.84MPa Seal Flow 30000 Cycles Washer Dishwasher Inlet Valve IQC
Pressure Cooker Safety Device Non-Reset Test Bench NL-FWF-1 Six Pressure Tests Working Safety Heat Resistance Internal Pressure Relief Burst GB 13623 GB 15066 Pressure Curve Recording
Model: NL-WKQ-28
A one-degree OFF-point drift in an incoming thermostat batch can fail a whole appliance run: ordinary ovens have unstable ramp rates and poor chamber uniformity, switching points are read by hand, and the action-plus-reset temperature loop is never closed, so incoming judgement stays guesswork.
The chamber tests snap-action and liquid-expansion thermostats on 28 stations, 1-28 parts per batch, direct or lead-wire mounting, NC or NO samples, and handles both OFF-above-ON and OFF-below-ON parts with action-only or action-plus-reset measurement. An eight-segment control profile runs fast ramps near 15C/min and controlled ramps at 1C/min with P1/P2 lead margins of at least 2C. Uniformity is graded 1C (40-150C), 1.2C (150-180C), 1.5C (180-220C) and 1.8C (220-280C); moving standard deviation stays below 0.10 under full load at 1C/min, and three consecutive runs repeat within 0.3C. Per-station temperature compensation offsets uniformity bias. Test range is 40-200C with a 0-300C grade-0.2 RKC controller and Pt100 control at 0.1C; temperature resolution 0.01C, detection resolution 0.1C, system accuracy within 0.2C. Average ramp rate is settable 0.5-2.0C/min with better than 0.1C/min near the action point and bath non-uniformity below 0.5C. LED states show each station, results are auto-judged, and batch max/min/mean plus per-part reset difference are statistically reported, stored, sent, recalled and printed. Xinje PLC with a Chinese touch screen sets model, batch and limits; AC220V 3.5kW.
GB/T 14536.10-2022 Particular requirements for temperature sensing controls for automatic electrical controls (current, effective 2023-07-01); GB/T 14536.1-2008 Part 1 General requirements; GB/T 22688-2008 Pressure-type thermostats; judgement values follow the product drawing or customer technical agreement.
Factory batch testing and incoming sampling at thermostat component plants; incoming verification of snap-action and liquid-expansion thermostats at appliance manufacturers; performance test support for third-party laboratories
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.
QQ
Service call
Back to the top