Incoming Thermostat Performance Tester NL-WKQ-28 28 Stations Snap-Action and Liquid-Expansion Types GB/T 14536.10 40-200C System Accuracy 0.2C 0.1C Per Min At Action Point Auto Judgement Statistics Printing

Model: NL-WKQ-28

The problem

A one-degree OFF-point drift in an incoming thermostat batch can fail a whole appliance run: ordinary ovens have unstable ramp rates and poor chamber uniformity, switching points are read by hand, and the action-plus-reset temperature loop is never closed, so incoming judgement stays guesswork.

Capability

The chamber tests snap-action and liquid-expansion thermostats on 28 stations, 1-28 parts per batch, direct or lead-wire mounting, NC or NO samples, and handles both OFF-above-ON and OFF-below-ON parts with action-only or action-plus-reset measurement. An eight-segment control profile runs fast ramps near 15C/min and controlled ramps at 1C/min with P1/P2 lead margins of at least 2C. Uniformity is graded 1C (40-150C), 1.2C (150-180C), 1.5C (180-220C) and 1.8C (220-280C); moving standard deviation stays below 0.10 under full load at 1C/min, and three consecutive runs repeat within 0.3C. Per-station temperature compensation offsets uniformity bias. Test range is 40-200C with a 0-300C grade-0.2 RKC controller and Pt100 control at 0.1C; temperature resolution 0.01C, detection resolution 0.1C, system accuracy within 0.2C. Average ramp rate is settable 0.5-2.0C/min with better than 0.1C/min near the action point and bath non-uniformity below 0.5C. LED states show each station, results are auto-judged, and batch max/min/mean plus per-part reset difference are statistically reported, stored, sent, recalled and printed. Xinje PLC with a Chinese touch screen sets model, batch and limits; AC220V 3.5kW.

NL test equipment

NL test equipment

Applicable standards

GB/T 14536.10-2022 Particular requirements for temperature sensing controls for automatic electrical controls (current, effective 2023-07-01); GB/T 14536.1-2008 Part 1 General requirements; GB/T 22688-2008 Pressure-type thermostats; judgement values follow the product drawing or customer technical agreement.

Key specifications

  • Basis: GB/T 14536.10-2022, GB/T 14536.1-2008, GB/T 22688-2008
  • Stations: 28 (1-28 parts per batch), snap-action and liquid-expansion types
  • Test range: 40-200C (controller range 0-300C, grade 0.2)
  • Sensor: Pt100, control accuracy 0.1C (RKC controller)
  • System accuracy: within 0.2C; resolution 0.01C / detection 0.1C
  • Uniformity: 1C at 40-150C; 1.2C at 150-180C; 1.5C at 180-220C; 1.8C at 220-280C
  • Dynamic stability: moving standard deviation below 0.10 at 1C/min full load
  • Repeatability: three-run correction Max-Min within 0.3C
  • Ramp: average 0.5-2.0C/min; better than 0.1C/min near action point; fast ramp about 15C/min
  • Bath non-uniformity: below 0.5C
  • Mounting: direct or lead-wire; NC/NO selectable
  • Output: auto judgement, LED states, batch statistics, storage and printing
  • Control: Xinje PLC + Chinese touch screen, per-station compensation
  • Power: AC220V, 3.5kW max; air-cooled compressor unit

Applications

Factory batch testing and incoming sampling at thermostat component plants; incoming verification of snap-action and liquid-expansion thermostats at appliance manufacturers; performance test support for third-party laboratories

About the manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.