Washers that finish the cycle with a puddle still in the drum, laundry dripping wet when pulled out, or machines that stop with a drain timeout fault the moment spin starts; open it up and the traction motor cable has slipped, the pull reaches its end but never returns, or the motor hums without moving. The causes are worn internal gears, lost pull force, a shortened stroke and a tired return spring. The line checks once that water drains; how much pull force decays and how much stroke shortens before the valve no longer opens fully are unknown, and the fault only shows up in customers’ homes.
GB 4706.1 (household appliances – general safety), GB 4706.24 (washing machines – particular requirements), IEC 60335-2-7 (washing machines – particular requirements), GB/T 4288 (electric washing machines for household use) and GB/T 2828 sampling; criteria can follow the customer’s standard and the drain valve construction.
Six stations running 24/7 turn a spring scale and a ruler into curves, cycle counts and trends, with pull decay and stroke loss rechecked round by round — so incoming traction motors and end-of-line washers can both be sampled batch by batch, stopping drain timeouts and standing water before shipment.
Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of drain traction motor pull and stroke life benches, washing machine test equipment, dishwasher test equipment, pump test bench and pump performance test systems and level sensor life test machines.
Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.