Whole-machine plugged aging runs rely on an operator watching the clock; on-off switching is manual, blocking orifices are inconsistent so data cannot be compared, and overheating at night goes unnoticed until a machine burns.
Thermal rise and endurance tester for whole appliances - floor scrubbers, vacuum cleaners and robot cleaners - covering AC and DC motor duty. Test cabinet with suction and exhaust piping, central control and temperature monitoring; on-off time 1-999999 (S/M/H units settable), counts 1-9999999; records per-station voltage, current, blocking orifice, run time and temperature; 9 blocking plates (10/13/15/16/19mm and 1/2, 3/8, 1/4, 1/8 inch); test current 1-30A; 4 stations per deck; K-type thermocouples 0-200C; 7-inch touch screen with Mitsubishi PLC and USB data export. AC220V 3.5kW (excluding load supply).
Thermal rise and endurance verification at floor-care and vacuum appliance plants; reliability laboratory build-up; sampling tests at certification bodies
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and lifetime technical service; 12-month warranty and lifetime spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.