Integrated cooker hoods that lose suction within a year, spill frying smoke into the kitchen and leave the shared duct clogged with grease usually turn out to have oil-coated impellers, greased-up ducts and a non-return flap stuck shut. Claimed airflow is rarely verified and grease separation goes unmeasured, so hood makers, motor suppliers and duct suppliers argue without a single number. An incoming check that stops at a noise test sees neither the decay nor the grease build-up until a whole batch reaches the service desk.
GB 4706.1 (household appliances – general safety), GB 4706.28 (range hoods – particular requirements), GB/T 17713 (range hoods – test methods for airflow, static pressure and grease separation) and GB/T 2828 sampling; criteria can follow the customer’s standard and the rated airflow and separation values.
One duct-type test section completes airflow, pressure, separation and noise sweeps in a single set-up, running 24/7, turning the days an operator would spend waving an anemometer at the outlet and weighing stripped parts into one automated sweep, with airflow decay and separation rechecked round by round — so incoming motors and end-of-line hoods can both be sampled batch by batch, stopping weak suction and clogged ducts before shipment.
Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of cooker hood airflow and grease separation benches, pump test bench and pump performance test systems, level sensor life test machines, dishwasher test equipment and washing machine test equipment.
Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.
QQ
Service call
Back to the top