Circulation pumps and booster pumps lose flow, fall short of head, cycle frequently or even burn out after six months of use — a common source of field failures and user complaints for appliance makers. Incoming inspection usually checks only start-up and external sealing, so the time-dependent decay of the flow-head curve and power draw is simply not visible; the deviation survives until the assembled machine runs, or until the end user. The cost in rework and reputation is significant.
GB/T 3216 (rotodynamic pumps – hydraulic performance acceptance tests), GB 4706.1 (household appliances – general safety) and IEC 60335-2-41 (pumps – particular requirements); acceptance criteria can follow the customer's standard.
Ten stations running 24/7 bring a single pump's flow-head measurement down from half a day by hand to a few minutes, while endurance ageing is completed within weeks — so incoming lots can be sampled batch by batch.
Guangdong Endurance Electronic Equipment Co., Ltd. — a non-standard testing equipment manufacturer of pump endurance and performance benches, pump test bench and pump performance test systems, level sensor life test machines, dishwasher test equipment and washing machine test equipment.
Keywords: pump test bench, pump performance test, level sensor life test, dishwasher test equipment, washing machine test equipment.