Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile
Your location: Home > 资讯中心
Recommended products

National Sales Hotline

0086-13416787649
Power cords fail at users within days? Flexing machine runs GB/T4706.1-2024 25.14 with 45-180 degree angles and auto stop

Power cords fail at users within days? Flexing machine runs GB/T4706.1-2024 25.14 with 45-180 degree angles and auto stop

Cord flexing life verification for appliances, power tools and IT equipment; endurance sampling at cord and plug plants;…

2026/10/21 20:51:21

Enclosure impact data missing at audits? Ball drop rig covers 0-1500mm with electromagnetic release and dual ball/slug tooling

Enclosure impact data missing at audits? Ball drop rig covers 0-1500mm with electromagnetic release and dual ball/slug tooling

Mechanical strength verification of housings and panels for appliances and IT/AV products; impact sampling of ecosystem …

2026/10/21 20:51:12

Plug torque judged by feel? Tester sets the axis 8mm behind the engagement face with 0.25Nm adjustable torque for export plugs

Plug torque judged by feel? Tester sets the axis 8mm behind the engagement face with 0.25Nm adjustable torque for export plugs

Factory inspection at plug and socket plants; incoming verification of couplers at appliance makers; safety-lab build-up…

2026/10/21 20:51:06

Solid insulation judgements disputed again and again? Fixture reproduces GB4943.1-2022 figure 29 with 100g rod and 5mm contact face

Solid insulation judgements disputed again and again? Fixture reproduces GB4943.1-2022 figure 29 with 100g rod and 5mm contact face

Process verification at adapter and charger plants; safety-lab build-up for certification bodies and third-party labs; m…

2026/10/21 20:50:59

Dishwasher Not Filling, or Overflowing Mid-Cycle and Soaking the Cabinet? NL-DLS-6 Water-Level Pressure Switch and Overflow Life Bench, Six Stations (level sensor life test)

Dishwasher Not Filling, or Overflowing Mid-Cycle and Soaking the Cabinet? NL-DLS-6 Water-Level Pressure Switch and Overflow Life Bench, Six Stations (level sensor life test)

Dishwashers that will not fill, will not stop filling, or overflow mid-cycle and run water out of the door onto the cabinet are the most direct complaints in the category. The cause is usually a level pressure switch tripping at the wrong pressure, an aged diaphragm, a pressure chamber clogged with scale and debris, or a stuck overflow float. The NL-DLS-6 measures trip points, life and overflow protection on six stations.…

2026/10/21 9:16:00

Mouldy Door Gasket Soaking the Floor and a Fogged or Cracked Window in Two Years? NL-WDS-4 Washer Gasket and Window Seal Ageing Bench (washing machine test equipment)

Mouldy Door Gasket Soaking the Floor and a Fogged or Cracked Window in Two Years? NL-WDS-4 Washer Gasket and Window Seal Ageing Bench (washing machine test equipment)

Front-load washers after a year or two show a black mouldy gasket, water seeping at the door and soaking the floor, and a window glass that fogs or cracks after a few hot-cold cycles, with only a complete door replacement as the fix. Gasket compression recovery, detergent ageing, glass thermal shock and bond strength are never measured. The NL-WDS-4 measures gasket ageing and window thermal shock on four stations.…

2026/10/21 9:16:00