8-Station Water Purifier Comprehensive Performance Test Bench NL-JSQ-8 Pure Water 0.2-2L/min Drain 0.3-12L/min Proof Pressure 0.05-3.5MPa Pulsation 5-30 Cycles per Minute Water Efficiency 900Hz Sampling GB 34914
Water-Related Appliance Overall Performance Test Bench NL-SSZT-1 Single Universal Station 0-300V 0-1.6MPa 0.1-16L/min 16-Channel Surface Temperature TDS Water Quality Variable Frequency Supply
Model: NL-SCBP-1
Pressure bearing parts such as condensers and copper tube coils face a two stage duty before they leave the factory: proof pressure around 6.3MPa held for 5 minutes with no visible deformation or weeping, then limit pressure around 18.6MPa held for 1 minute without bursting. When a specimen does burst the impact and spray are violent; manual pressurisation is dangerous and leaves no evidence chain behind.
The machine runs two stage pressure and burst tests on condensers and copper tube coils. Basic proof mode fills the specimen with water, vents the air and raises pressure slowly to the test point such as 6.3MPa held for 5 minutes with no macroscopic deformation or seepage allowed; limit mode continues to the ultimate pressure such as 18.6MPa held for 1 minute with no rupture or leakage, while deformation that does not cause leakage is acceptable. Burst pressure spans up to 20MPa; sensors cover 0-20MPa static and 0-16MPa burst at 0.5 percent accuracy, sampling above 60Hz with 0.01MPa resolution, and the low pressure band 0.5 to 2.0MPa also runs normally. The guard chamber measures at least 1000 by 1000 by 1000mm with a bullet resistant observation window and manual latch; the door cannot open before pressure is released. A servo pressure regulation system offers automatic and manual pressurisation plus automatic and manual venting; on leakage the machine stops pressurising and records the highest pressure reached. Hold time spans 0 to 3000 seconds with an alarm at the end of hold. A 100L 304 stainless feed tank refills automatically with inlet filtration and test water drains without recirculation. Guard fixtures protect operator and equipment at the moment of rupture, a venting fixture clears trapped air first, PLC and touch screen keep data long term with USB export, and the supply is 380V at 3.5kW.
GB/T 35937-2018 Performance test methods for household and similar drinking water treatment units (current); GB/T 30307-2023 Household and similar drinking water treatment units (current, replaces the 2013 edition); QB/T 4144-2019 Household and similar pure water treatment units (current); test pressures, hold times and judgement follow the customer technical agreement.
Pressure proof and burst testing of air conditioner condensers and heat exchanger copper coils; pressure bearing parts of water purifiers and drinking water appliances; factory sampling at copper tube and heat exchange component plants; rupture performance verification in third party laboratories
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.