Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing
Central Sensor Diaphragm Endurance Test Machine NL-ZXCG-2 Two Stations Stepper Press-Hold-Release Automatic Cycle 0-5000N Force Monitoring Over 20000N Capacity 1-10 Cycles per Min 999999 Counts GB/T 14536.7-2024 Electric Pressure Cooker Sensor Testing
High Frequency Solenoid Valve Flow-Current Characteristic Test Machine NL-HWHY-2 Two Stations 12 Characteristic Tests Hysteresis Response Repeatability 0-3000mA Drive 100-4000Hz Dither 50-400mA 20kHz Sampling 1-150bar plus or minus 1 percent FS GB/T 15623 Electrically Modulated Valve Testing
Motor Slide Bearing Endurance Test Bench NL-ZC-1 Constant Temperature Chamber Radial Load 0-120N Servo 1-3000rpm within 5rpm Ambient plus 20 to 80C 608/6002 Fixtures 30-Channel Temperature Logging GB/T 2688 Micro Motor Noise Life Research
Model: NL-RGZ-1500
Capacity drop, shell temperature rise and controller derating under solar load cannot be reproduced by estimation or by waiting for summer. Ordinary lamp arrays give uneven irradiance and a spectrum unlike sunlight, so data changes from room to room; and with flammable refrigerants such as R32 or R290 inside the unit under test, nobody wants to sign off on hot lamps sharing a room with a leak.
Two matrices of about 1m2 each form a 2m2 irradiation plane, and each matrix tilts independently to cover the side and the top of the unit under test. Irradiance is continuously adjustable from 400 to 1500W/m2, reaching 1500W/m2 on the target plane at 1 to 2m distance with parallel light output. Spectral match is AM1.5G Class A with interval ratios of 0.75 to 1.25, irradiance accuracy within plus or minus 2 percent and non-uniformity within plus or minus 2 percent across the 2m2 plane. Each set carries three total irradiance sensors covering 0-2000W/m2 and 100-3000nm at plus or minus 2 percent for live display and closed-loop control. The frame lifts from 0 to 2m to suit different unit heights and its base clears the main refrigerant piping so the array can sit close to the cabinet. Aluminium profile or painted steel construction keeps the frame rigid, with lockable castors and fork-lift access for moving between laboratories. Flammable refrigerant interlock uses dedicated R454B, R32 and R290 sensors that cut power at 10 percent LEL, and only the sensor for the refrigerant in use is powered to extend its life. The control cabinet can be integrated or split with 10m or longer output cables and quick connectors, optionally on a mobile trolley. Lamp life is at least 3000h with easy replacement and anti-scald guards, and a touch screen sets switching, irradiance and tilt angle while displaying live irradiance. The equipment suits laboratories at 0-60C and 30-90 percent RH.
GB/T 6495.9-2025 Photovoltaic devices, Part 9 Classification of solar simulator characteristics (current, effective 2026-07-01, identical to IEC 60904-9:2020); IEC 60904-9:2020 solar simulator classification, Class A requiring spectral match 0.75-1.25, non-uniformity within 2 percent and instability within 2 percent; GB/T 7725-2022 Room air conditioners as the appliance performance reference; GB 4706.32 particular requirements for heat pumps, air conditioners and dehumidifiers as the safety reference.
Solar load capacity and shell temperature testing of air conditioners; light coupling verification for PV-driven and storage air conditioners; solar aging simulation for outdoor cabinets and automotive parts; lighting environment support in third-party laboratories
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.
QQ
Service call
Back to the top