Ceramic Part Aging Pressure Test Apparatus NL-TCH-15 15MPa Pressure Vessel GB4706.1 Clause 22.32 Ceramic Material Parts Settable Holding Time Bench Type with Sealed Lid and Safety Protection
Salt Spray Test Chamber NL-120 GB/T10125 NSS AASS CASS Three Modes Chamber 35 1C Saturation Barrel 47 1C 1200x1000x600mm PVC Body Pneumatic Lid Metal Plating Corrosion Testing
Gas Stove Whole-Unit and Fan Assembly Combined Endurance Test Bench NL-ZJFJ-1 GB16410-2020 Pneumatic Knob Press Rotation Ignition Large-Small Flame Cycle 0-999999 Cycles Range Hood Fan 2 Stations On-Off 10-30 Cycles Per Minute
Silicone Seal Fatigue Tension-Compression Load Testing Machine NL-LLJ GB/T16491-2022 1T Capacity 0.5 Grade Load Cell 800mm Stroke 0.001-500mm/min Cycle Load Dwell Triple Settable Seal and Rubber Parts
Model: NL-ZLYL-1
Appliances charged with R290, R32 or R600a must be tested against simulated leakage scenarios under the standard. Without a controlled leakage-test environment - where leak points can be placed, concentration sampled and ventilation verified - the test is neither repeatable nor safe, and certification queues simply lengthen.
The room is built as one line: enclosure - leak - sampling - interlock. The enclosure is sealed and ventilated to the standard clauses, and simulated leak points are placed along the sample refrigerant circuit and adjusted per model. After release, flammable-refrigerant concentration probes sample continuously, so the concentration distribution and dilution process are fully recorded. Flammable gas detection, alarm devices and forced ventilation are interlocked: any point over limit trips the ventilation and the test stays under control throughout. Air-conditioning units (R290/R32/R1270) and refrigerator units (R600a) share one room; changing model only means repositioning leak points and sampling, with no second construction. Enclosure, sampling lines, ventilation and electrics are delivered complete as a turnkey project.
Built to GB 4706.32-2012 Safety of household and similar electrical appliances - Particular requirements for heat pumps, air-conditioners and dehumidifiers, clauses 22.107, 22.108 and 22.109, and the corresponding clauses of GB 4706.13-2014 for refrigerating appliances; refrigerant, sampling and ventilation parameters follow the sample specification.
Flammable-refrigerant safety rooms at air-conditioner and refrigerator plants; structural safety verification and certification support for R290/R32/R600a models; capability extension for third-party laboratories
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.
QQ
Service call
Back to the top