Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile
Your location: Home > 供应产品
Supply Refrigerator and Display Cabinet Door Cycle Tester NL-KGM2 Rotary Cylinder Drive Double Doors 700-1400mm One Million Cycles

Supply Refrigerator and Display Cabinet Door Cycle Tester NL-KGM2 Rotary Cylinder Drive Double Doors 700-1400mm One Million Cycles

Door cycle tester for refrigerators, freezers and display cabinets: rotary cylinder drive, single or double doors, samples 700-1400mm, 0-135 degrees, up to one million cycles with live current monit… 【Details】
Supply Kitchen Sink Load-Bearing Deformation Tester NL-SCCZ-1 Servo Loading 1274N Hold 1h GB/T 38474-2020 6.7 for Stainless Steel Sinks

Supply Kitchen Sink Load-Bearing Deformation Tester NL-SCCZ-1 Servo Loading 1274N Hold 1h GB/T 38474-2020 6.7 for Stainless Steel Sinks

Sink load-bearing tester: servo loading to 1274N static load, 1 h hold, deformation read as l2 minus l1 against the 3mm limit, three-side adjustable support, GB/T 38474-2020 5.6 and 6.7. Tel 0760-88… 【Details】
Supply Water Servo Valve Performance Test Bench NL-SFW-6 Six Stations 42 Quick-Change Fixtures Flow 2-25 L/min Frequency 0-500Hz Q-alpha Curve Envelope Judgement

Supply Water Servo Valve Performance Test Bench NL-SFW-6 Six Stations 42 Quick-Change Fixtures Flow 2-25 L/min Frequency 0-500Hz Q-alpha Curve Envelope Judgement

Six-station water servo proportional valve test bench: flow 2-25 L/min at 1 percent accuracy, frequency 0-500Hz at 0.1Hz resolution, variable frequency constant pressure 0-0.6MPa, envelope curve jud… 【Details】
Supply Electronic Expansion Valve Performance Tester NL-PZF-2 Two Stations Flow Characteristic 0.1MPa Nitrogen Leakage at 1MPa Closed State Open-Pulse Auto Capture JB/T 10212

Supply Electronic Expansion Valve Performance Tester NL-PZF-2 Two Stations Flow Characteristic 0.1MPa Nitrogen Leakage at 1MPa Closed State Open-Pulse Auto Capture JB/T 10212

Electronic expansion valve comprehensive tester: two stations, flow characteristic at 0.1MPa nitrogen with five forward and reverse points, leakage at 1MPa fully closed, automatic open-pulse capture… 【Details】
Supply Four-Way Reversing Valve Test Bench NL-STF-1 One Performance + Two Life Stations Max Differential 0-5MPa Internal Leakage 0-2.5MPa Mid Flow 0-200L/min Coil 0-300V Inverter 1P-20P Fixtures

Supply Four-Way Reversing Valve Test Bench NL-STF-1 One Performance + Two Life Stations Max Differential 0-5MPa Internal Leakage 0-2.5MPa Mid Flow 0-200L/min Coil 0-300V Inverter 1P-20P Fixtures

Four-way reversing valve comprehensive test bench: one performance station plus two life stations, max operating differential 0-5MPa, internal leakage 0-2.5MPa, mid flow 0-200L/min, coil supply 0-30… 【Details】
Supply Grease Resistance-to-Gas Test Apparatus NL-YZRN-1 Bath 0-50 Degrees C Gas Pressure 2000-5000Pa GB 16410 5.4.2.3 Dual Temperature 20C/4C Mass Change

Supply Grease Resistance-to-Gas Test Apparatus NL-YZRN-1 Bath 0-50 Degrees C Gas Pressure 2000-5000Pa GB 16410 5.4.2.3 Dual Temperature 20C/4C Mass Change

Grease resistance-to-gas test apparatus for cooker taps: water bath 0-50 degrees C settable, gas pressure 2000-5000Pa, dual temperature assessment at 20C and 4C per GB 16410 5.4.2.3. Tel 0760-885009… 【Details】
Supply Gasket Resistance-to-Gas Test Apparatus NL-DQPJ-1 n-Pentane Soaking 23C Plus Minus 2C Thermostatic Bath 24h Mean Permeation Calculation CNCA-C24-01 Annex 5.4.2.2

Supply Gasket Resistance-to-Gas Test Apparatus NL-DQPJ-1 n-Pentane Soaking 23C Plus Minus 2C Thermostatic Bath 24h Mean Permeation Calculation CNCA-C24-01 Annex 5.4.2.2

Gasket resistance-to-gas test apparatus: n-pentane soaking, 23C plus or minus 2C thermostatic bath for 24h, mean hourly permeation calculation, with two pressure fixtures and a precision balance. Te… 【Details】
Supply Compressor Locked-Rotor Test Bench NL-YSDZ-2 Two Stations Single/Three Phase 100A per Station 15-Day Locked Rotor Four Safety Checks GB 4706.17 Protector Matching

Supply Compressor Locked-Rotor Test Bench NL-YSDZ-2 Two Stations Single/Three Phase 100A per Station 15-Day Locked Rotor Four Safety Checks GB 4706.17 Protector Matching

Compressor locked-rotor test bench: two stations, single/three-phase switching, 100A per station, continuous 15-day locked-rotor runs, four on-line safety checks, protector matching per GB 4706.17. … 【Details】
Supply Thermostatic Expansion Valve Endurance Tester NL-RZP-5 Five Stations 4.3MPa Pressure Cycling 0-500000 Cycles Power-Failure Memory JB/T 10212

Supply Thermostatic Expansion Valve Endurance Tester NL-RZP-5 Five Stations 4.3MPa Pressure Cycling 0-500000 Cycles Power-Failure Memory JB/T 10212

Thermostatic expansion valve endurance tester: five parallel stations, 4.3MPa pressure cycling with alternating 1.5s solenoid phases, 0-500000 preset cycles with power-failure memory. Tel 0760-88500… 【Details】
Tableware Dishwashing and Microwave Heating Combined Tester NL-CJ-02 EN 12875-1 Cycling + BS EN 15284 Microwave 2450MHz 0-1000W 72000J/468000J Closed-Loop Energy Fiber Temperature Sensing

Tableware Dishwashing and Microwave Heating Combined Tester NL-CJ-02 EN 12875-1 Cycling + BS EN 15284 Microwave 2450MHz 0-1000W 72000J/468000J Closed-Loop Energy Fiber Temperature Sensing

Tableware durability combined tester: EN 12875-1 dishwashing cycles plus BS EN 15284 microwave heating in one twin-module machine, 2450MHz 0-1000W continuously variable, 72000J/468000J closed-loop e… 【Details】
High-Low Temperature Fan Motor Accelerated Life Test Chamber NL-FJSM-24 24 Stations 500-750mm and 1050mm Fans -40 to 70C 20 to 98 percent RH Programmable

High-Low Temperature Fan Motor Accelerated Life Test Chamber NL-FJSM-24 24 Stations 500-750mm and 1050mm Fans -40 to 70C 20 to 98 percent RH Programmable

Large-diameter commercial fan accelerated life chamber: 24 stations for 500-750mm fans plus 4 stations for 1050mm fans, -40 to 70C with 20 to 98 percent RH programmable cycles. Tel 0760-88500902 / 1… 【Details】
Control Board Dual-85 Test Chamber NL-DKBK-85 24 Stations -40 to 150C 20 to 98 percent RH 0-40A Dual Load Channels Water-Heater PCB Aging

Control Board Dual-85 Test Chamber NL-DKBK-85 24 Stations -40 to 150C 20 to 98 percent RH 0-40A Dual Load Channels Water-Heater PCB Aging

Control board dual-85 reliability chamber: 24 drawer stations on two levels, -40 to 150C and 20 to 98 percent RH, 0-40A adjustable dual-channel load cabinet, plus complete post-test analysis instrum… 【Details】