Guangdong Endurance Electronic Equipment Co., LtdMain products: testing machine
National Service Hotline :0086-13416787649 Wechat
Official wechat
Mobile
Mobile
Your location: Home > 资讯中心
Recommended products

National Sales Hotline

0086-13416787649
Water Purifier Joints Weeping Once Plumbed In, Hoses Bursting Under a Surge? NL-WHP-4 Whole-Machine Water Hammer Pulse & Line Pressure Bench Runs Four Stations (pump performance test)

Water Purifier Joints Weeping Once Plumbed In, Hoses Bursting Under a Surge? NL-WHP-4 Whole-Machine Water Hammer Pulse & Line Pressure Bench Runs Four Stations (pump performance test)

Joints weeping once the purifier is plumbed in, or inlet hoses bursting under a pressure surge, are costly complaints: loose quick-connectors and insufficient hose pressure margin fatigue progressively under water hammer from fast valve action. Incoming checks usually stop at components, so the whole-machine water hammer and pressure margin stay hidden. The NL-WHP-4 measures both in one pass.…

2026/10/13 9:13:53

Health Pot Scaling and Yellowing Within Two Months, Thermostat and Dry-Boil Protection Failing? NL-TEA-6 Health Pot Heating & Thermostat Life Tester Runs Six Stations (level sensor life test)

Health Pot Scaling and Yellowing Within Two Months, Thermostat and Dry-Boil Protection Failing? NL-TEA-6 Health Pot Heating & Thermostat Life Tester Runs Six Stations (level sensor life test)

Health pots scaling and yellowing within two months, with the thermostat drifting and dry-boil protection failing to trip, is a frequent service issue: heating-disc power decay, thermostat set-point drift and level-detection failure all unbalance heating and control. Incoming checks stop at power-up, so the drift under heating cycles stays hidden. The NL-TEA-6 runs heating cycles and control accuracy in one pass.…

2026/10/13 9:13:53

Proportion Valve Flow Jumping With a Slight Opening Change, Drifting After Six Months? NL-PRV-8 Solenoid Proportion Valve Flow Linearity & Hysteresis Endurance Bench Runs Eight Stations (pump test bench)

Proportion Valve Flow Jumping With a Slight Opening Change, Drifting After Six Months? NL-PRV-8 Solenoid Proportion Valve Flow Linearity & Hysteresis Endurance Bench Runs Eight Stations (pump test bench)

Gas water heaters and boilers showing fluctuating outlet temperature after six months often trace to the proportion valve: hysteresis grows, linearity degrades and the same opening gives a different flow. Linearity, hysteresis and response time are rarely measured at incoming inspection, so the drift reaches the user. The NL-PRV-8 tests the opening-flow curve and hysteresis in one pass.…

2026/10/13 9:13:53

No bench for surge-then-rated combination switching duty? 8-station on-off life bench runs 0.1-100A adjustable loads with 30 programmable routines

No bench for surge-then-rated combination switching duty? 8-station on-off life bench runs 0.1-100A adjustable loads with 30 programmable routines

Type testing and life sampling at proximity/micro/limit switch plants; UL61058-1 surge combination verification for appl…

2026/10/12 20:43:56

Point-by-point manual flow-pulse calibration too slow? 1-station bench scans duty points automatically under constant pressure with automatic OK/NG judgement

Point-by-point manual flow-pulse calibration too slow? 1-station bench scans duty points automatically under constant pressure with automatic OK/NG judgement

Factory performance inspection and life sampling at water flow sensor plants; incoming inspection for water-heater, wate…

2026/10/12 20:43:52

Refrigerator thermostats drifting after months in the field? 10-station pressure-actuation endurance tester runs 210240 loaded cycles under climate cycling automatically

Refrigerator thermostats drifting after months in the field? 10-station pressure-actuation endurance tester runs 210240 loaded cycles under climate cycling automatically

Type testing and endurance sampling at refrigerator/freezer thermostat plants; loaded life verification of vapour-pressu…

2026/10/12 20:43:49